Space maintainer ₹ 4500/-
A single piece 3D printed Band and loop Space maintainer made of CoCr alloy , traditional design modern approach to manufacturing. No Seperators or band transfer required.
TPA ₹ 7500/-
Transpalatal Arch for orthodontic Anchorage, 3D printed by selective laser melting, traditional design with or without center loop can be designed as required. Hooks for retraction of intrusion by using elastics can also be placed and oriented as per requirement. No seperators or band transfer required, can be fabricated with crescent/half bands/ buccal side open bands.
Nance palatal arch ₹ 7500/-
A single piece 3d Printed appliance can be had with a acrylic button on palate or the metal button. No seperators or band transfer required, can be fabricated with crescent/half bands/ buccal side open bands.
Tongue thrust / Thumb sucking habit breaker ₹ 7500/-
A single piece 3d Printed appliance can be had with sharp/blunt spikes being in orientation and length of choice and location in palate as per clinicians choice. No seperators or band transfer required, can be fabricated with crescent/half bands/ buccal side open bands. Advised to have rests on palatal surfaces of canines (decidious or permanent).
Lingual arch ₹ 7500/-
A single piece 3d Printed appliance following the contour of lingual surface of mandible. Rests on lower anteriors as per reuqirements of clinician. No seperators or band transfer required, can be fabricated with crescent/half bands/ buccal side open bands. Advised to have rests on palatal surfaces of canines (decidious or permanent).
Rapid palatal expander ₹ 11,500/-
Rigid SlM framework, bands can be placed on decidious molars also. Full, half, crescent, buccal open band options available which can be place on individual tooth as required. Hooks for elastics or buccal arms extension for face mask can also be placed as optional extras if required.
MARPE ₹ 15,500/-
Records Required :- Maxilla Scan with full palate, CBCT Maxilla (Diacom Data / .dcm files) . A silicon impressions accepted if scanner not available. A proper impression with good teeth margin defination and proper palate is required to fabricate a well fitting appliance. Improper impressions will be rejected.
Rigid SlM framework. Full, half, crescent, buccal open band options available which can be place on individual tooth as required. Hooks for elastics or buccal arms extension for face mask can also be placed as optional extras if required.
TADS NOT INCLUDED IN PACKAGE. We support integration of following company’s TADs in our MARPE fabrication :-
- bioray
- medusa by favanchor
- dentos
- tuskdenta
- sk surgicals
2 TADs for cases below 17 years, 4 TADs for age 17 and above are advised. We do not deal in TADs of above companies and they cannot be provided by us even on special request.
D3D MARPE ₹ 15,500/-
Hybrid Hyrax / Brolex/ bone borne expander etc fabricated using 2 piece TADs from Digant’s 3D Orthodontics.
Records required :- Maxillary scan full palate, CBCT Maxilla (DIACOM Data, .dcm files). A silicon impressions not accepted.
Steps in Workflow :-
- intra oral scan and CBCT submission
- 3D printed guide for D3D TADs placement received by clinician
- clinician places TADs using the guide
- Intra Oral scan of maxilla taken after TADs placement and submitted
- Appliance design link received by clinician for changes or approval in design
- On approval of design appliance fabricated and sent to clinician
TADs charged extra at 2300/- per piece (includes the cover screw)
D3D Distalizer Unilateral / Bilateral ₹ 15,500/- / 18,500/-
Silm Line hyrax oriented along the framework in line of orientation of the molar distalization as per clinicians advice. Unilateral Distalizer can be extended to molar on opposite sides or avoided also . The appliance can be use prior to aligner starting and aligners fit snugly over the bands of the appliance. Attachment of choice can be placed on buccal side of the bands fabricated based on clinicians choice. buccal side of the band can also be kept open if we want to bond buccal tube in future.
Activation Protocol : 90 degrees per week (i.e. 0.2mm distalization per week)
Steps in Workflow :-
- intra oral scan and CBCT submission
- 3D printed guide for D3D TADs placement received by clinician.
- clinician places TADs using the guide.
- Intra Oral scan of maxilla taken after TADs placement and submitted.
- Appliance design link received by clinician for changes or approval in design
- On approval of design appliance fabricated and sent to clinician
TADs charged extra at 2300/- per piece (includes the cover screw)
Distalizer only possible with D3D systems
D3D Expander + Distalizer Unilateral / Bilateral ₹ 18,500/- /21,500/-
Expansion Hyrax in center with slim line hyrax oriented laterally along the direction of required molar distalization as per clinicians requirements. Bands on molars for distalization. Expansion protocol as per clinicians choice, Distalization activation 90 degrees per week (i.e. 0.2mm per week)
Steps in Workflow :-
- intra oral scan and CBCT submission
- 3D printed guide for D3D TADs placement received by clinician.
- clinician places TADs using the guide.
- Intra Oral scan of maxilla taken after TADs placement and submitted.
- Appliance design link received by clinician for changes or approval in design
- On approval of design appliance fabricated and sent to clinician
TADs charged extra at 2300/- per piece (includes the cover screw)
Expander + Distalizer only possible with D3D systems
Twin Block ₹ 10,000/-
Claspless aligner like design with blocks on occlusal surface of teeth similar to Twin Blocks, 3D printed using biocompatible transperent resin, colour options not available. Tooth coverage can be altered as per clinicians discretion.
Records required :- Intra Oral Scan with advancement bite as per the wax bite we take for twin block fabrication. one can take a wax bite and place it in patient’s mouth after clearing the wax on buccal side and take scan in the bite scan step – this would make and scan orientation in advancement bite.
Included in price :-One repeate fabrication of appliance in case of breakage or misfit due to eruption of permanent teeth.